SELF ASSESSMENT SECTION (1)


สำหรับชาววิสัญญีผู้ใฝ่รู้ไม่มีที่สิ้นสุด

ช่วงนี้น้องนักเรียนวิสัญญีพยาบาลใกล้สอบ พี่เลยค้นๆข้อสอบฝรั่งมาอ่าน...อ่านแล้วก็เคาะขี้เลื่อยออกจากหัวได้โข...

 

...ทฤษฎีอย่างนี้เหมาะสำหรับน้องๆและคุณหมอผู้อยู่ในวัยใฝ่รู้  อย่างผู้เขียนคงได้แค่อ่านให้ได้รู้และทบทวนหรอกนา  ให้กลับมาจำก็จำไม่ไหวแล้วววว.....

 

ขอไปเที่ยวเสาะแสวงหามาให้สนุกกว่า

 

(ขอเลือกมาเฉพาะข้อที่คิดว่าพยาบาลน่ารู้ก่อน...)

Question 1

The following statements about suxamethonium are true

A.    It is the muscle relaxant most frequently implicated in allergic reactions

B.     It is metabolised to two molecules of acetylcholine by the action of plasma pseudocholinesterase

C.     The rise in intraocular pressure caused by its administration lasts for up to half an hour

D.    It may cause a bradycardia due to stimulation of nicotinic receptors

E.     The Phase II block seen after repeated administration or infusion is reliably reversed using neostigmine

Question 15

The following are true regarding breathing systems

A.    The Bain circuit is an example of a Mapleson A system

B.     The Bain circuit is more efficient than the Lack circuit during spontaneous breathing

C.     In the Bain circuit, fresh gas flow occurs through the outer tube

D.    During spontaneous breathing, the Lack circuit requires a fresh gas flow rate of twice the alveolar minute ventilation to prevent rebreathing

E.     The Lack circuit may be used to ventilate the patient's lungs with the Penlon Nuffield 200 ventilator

 (หากต้องการดูคำเฉลย ให้ดาร์คพื้นขาวด้านล่างนะคะ...คำตอบอยู่ที่นั่นค่ะ...)

Answer 1

A. true B. false C. false D. false E. false

It is composed of two molecules of acetylcholine, but is metabolised to the relatively inactive succinyl monocholine. The rise in intraocular pressure caused by suxamethonium alone is brief, lasting for a few minutes. The bradycardia is caused by activation of muscarinic receptors. Phase II block does exhibit the characteristics of non-depolarising block but is not reversed by anticholinesterases.

 

 

Answer 15

A. false B. false C. false D. false E. false

 

 

The Bain circuit is the coaxial version of the Mapleson D system. Fresh gas flow (FGF) is supplied through a narrow inner tube. The patient's expired gases pass through the outer tube and are vented to atmosphere. This sytem is inefficient during spontaneous breathing but efficient during controlled ventilation. A FGF rate of between two to three times minute volume (200- 250 ml/kg/min) may be required during spontaneous ventilation to prevent rebreathing. FGF of between 70 and 80 ml/kg/min is required during controlled ventilation to prevent rebreathing.

The Lack circuit is the coaxial version of the Mapleson A system. The outer tube supplies inspired gas from the reservoir bag and the patient exhales through the inner tube. This system is inefficient during controlled ventilation but efficient during spontaneous breathing. During controlled ventilation, the FGF rate must be at least three times alveolar minute volume to prevent rebreathing. If the system is functioning correctly and no leaks are present, a FGF rate equal to the patient's alveolar minute ventilation is sufficient to prevent rebreathing. In practice, a higher FGF rate (equal to the minute volume) is selected to compensate for leaks. Unlike the Bain circuit, the Lack circuit does not permit the use of ventilators to provide controlled ventilation.

Ref: A R Aitkenhead, G Smith. Textbook of Anaesthesia,

 ขอให้สนุกกับการทำข้อสอบนะคะ

(คำตอบเฉลยไว้ให้ด้านล่างของคำถามแล้วค่ะ...อิอิ...)

 (ที่มา : http://www.nda.ox.ac.uk/wfsa/html/u17/u1716_01.htm )

 

หมายเลขบันทึก: 285022เขียนเมื่อ 8 สิงหาคม 2009 15:54 น. ()แก้ไขเมื่อ 13 มิถุนายน 2012 15:18 น. ()สัญญาอนุญาต: ครีเอทีฟคอมมอนส์แบบ แสดงที่มา-ไม่ใช้เพื่อการค้า-อนุญาตแบบเดียวกันจำนวนที่อ่านจำนวนที่อ่าน:


ความเห็น (2)

ขอบคุณค่ะพี่แก้วคะ

ทบทวนความรู้ทางวิชาการบ้างเท่านั้นค่ะ เพราะนานๆไปชักลืมเหมือนกัน

..อ่านๆไปเรื่อยๆก็สนุกดีค่ะ

พบปัญหาการใช้งานกรุณาแจ้ง LINE ID @gotoknow
ClassStart
ระบบจัดการการเรียนการสอนผ่านอินเทอร์เน็ต
ทั้งเว็บทั้งแอปใช้งานฟรี
ClassStart Books
โครงการหนังสือจากคลาสสตาร์ท